Standard Test Chamber Features:
-
Programmable logic microprocessor controller with LCD Control
Panel with message center, 4 x 20 character LCD display.
-
Humidity control.
-
Continuous product temperature display.
-
Air probe with air temperature
Hi/Lo alarms audible & visual.
-
Programmable ramp soak feature.
-
2
levels of user password protection (set points and parameters).
-
100 event alarm logging including Date/Time Stamp and product
temperatures stored in nonvolatile Flash memory.
-
Integrated Hi/Lo alarm tests.
-
Door ajar alarm with adjustable delay time period.
-
Power failure alarm.
-
Remote alarm contacts.
-
Stainless steel interior.
-
Coated evaporator.
-
Key lock door and casters.
-
Interior drain with plug.
-
Exterior finish of heavy gauge steel painted with white scratch
resistant baked enamel AND 3
epoxy coated wire shelves.
-
Thermostatically controlled door frame heater.
-
Industrial quality refrigeration system.
-
The
complete cabinet is UL and C-UL listed.
Test Chamber
Options (both units):
-
Temperature chart recorder & chart paper 2 pen
-
Electrical duplex outlet
-
RS485 communication output
-
Access port 2”
with sleeve and cover
-
Sensor access port
1”
diameter
-
Shelf with clips
-
Stainless steel exterior
-
4-20 MA output (temperature only)
-
Export crating
Performance
Ratings for
SCRI-1S24
Temperature ONLY Test Chamber:
Temperature
Variation:
+/-0.5°C @ 4°C to 70°C. The published temperature variation is derived from the
maximum deviation of the thermocouple located nearest the chamber
geometric center during the entire test period. (i.e. 25.0°C min and 26.0°C max
divided by two would be a variation of +/-0.5°C).
Temperature
Uniformity:
+/-1°C @ 4°C to 70°C.. The published temperature uniformity is derived from the
maximum deviation of 9 thermocouples are placed on 3 horizontal planes,
each plane having the thermocouples evenly spaced diagonally across the shelf
from the left and right inner wall, and the middle sensor placed in the
approximate geometric center of the shelf.
Performance HSCRI-1S24
Humidity and Temperature Test Chamber
Humidity
Variation:
+5% @ 5°C to 60°C and RH within performance graph. Humidity variation is
derived from the maximum deviation of the humidity sensor during the test
period.
Performance data is based on 23°C, 50%RH ambient conditions, type
T-24 Ga. thermocouples with 1.0oz. Brass slugs attached and no product in the
chamber. Data may vary if; ambient conditions change, product load is added, or
other changes cause interference to chamber airflow.
Humidification /
Dehumidification:
Relative humidity is induced by a highly efficient centrifugal
atomizer with a sealed motor and low maintenance reservoir. Dehumidification is
achieved by the use of a separate dehumidification latent coil. Both systems are
precisely controlled by the programmable logic microprocessor.
The humidity controller utilizes a dry capacitance type sensor for
rapid response to humidity changes with exceptional accuracy. The humidifier
requires a water source with low mineral content; i.e., resistance of 0.5 - 1.0
megohm and a pressure of 10 – 100 psi. Reverse osmosis treated water is
recommended. The water supply connection requires 1/4” plastic or copper tubing.
Specifications
|
|
|
|
|
|
Humidified Units |
HSCRI-1S24 |
HSCRI - 2S52 |
HSCRI - 3S80 |
|
Non-Humidified Units |
SCRI-1S24 |
SCRI - 2S52 |
SCRI - 3S80 |
|
|
|
|
|
|
Dimensions |
|
|
|
|
|
|
|
|
|
Crated Height (in) (cm) |
83” (211) |
83” (211) |
83” (211) |
|
Crated Width (in) (cm) |
31-7/8” (81) |
59” (150) |
85-1/4” (216) |
|
Crated Depth (in) (cm) |
38-7/8” (98) |
38-7/8” (98) |
38-7/8” (98) |
|
Crated Weight (lbs) (kg) |
407 (184) |
651 (295) |
840 (381) |
|
|
|
|
|
|
Interior Height (in) (cm) |
59” (149) |
59” (149) |
59” (149) |
|
Interior Width (in) (cm) |
23-1/2” (59) |
51” (129) |
78-1/2” (199) |
|
Interior Depth (in) (cm) |
30” (76) |
30” (76) |
30” (76) |
|
|
|
|
|
|
Overall Height (in) (cm) |
79-5/8” (202) |
79-5/8” (202) |
79-5/8” (202) |
|
Overall Width (in) (cm) |
27-1/2” (69) |
55” (139) |
82-1/2” (88) |
|
Overall Depth (in) (cm) |
34-7/8” (88) |
34-7/8” (88) |
34-7/8” (88) |
|
|
|
|
|
|
Gross Cubage (ft.3) (m3) |
24 (0.6) |
52 (1) |
80 (2) |
|
Shelf Area (sq. ft.) (m2) |
12.8 (1) |
28.5 (2) |
42.8 (3) |
|
|
|
|
|
|
Standard Cabinet |
|
|
|
|
|
|
|
|
|
Number of Shelves |
3 |
6 |
9 |
|
Number of Casters |
4 |
4 |
6 |
|
Condensing Unit Size |
1/3 HP |
1/2 HP |
3/4 HP |
|
Refrigerant |
R-134a |
R-134a |
R-134a |
|
Maximum Fuse Size AMPS |
15 |
20 |
30 |
|
Total Amp Draw /8 |
11.7 |
13.4 |
18.79* |
|
Total Amp Draw /5 |
11.3 |
N/A |
N/A |
|
|
|
|
|
|
|
|
|
|
|
Voltages & Power Description |
NEMA Plug |
NEMA Receptacle |
|
|
|
|
|
|
|
230V, 1PH, 50HZ |
Module (IEC 60320) |
Customer Supplied |
|
|
115/208-230V/1PH60HZ |
L-14-20P |
L-14-20R |
|
|
115/208-230V/1PH60HZ |
L-14-30P
(3S80) |
L-14-30R
(3S80) |
|
IDS Order #
Description
SCRI-1S24
1 Solid Door
Temperature ONLY Test Chamber
HSCRI-1S24 1
Solid Door
Humidity and Temperature Test Chamber
SCRI-2S52
2 Solid Door
Temperature ONLY Test Chamber
HSCRI-2S52 2
Solid Door
Humidity and Temperature Test Chamber
SCRI-3S80
3 Solid Door
Temperature ONLY Test Chamber
HSCRI-3S80 3
Solid Door
Humidity and Temperature Test Chamber
*Always note electrical
requirements (shown above) for your application.
Specification sheet.
|