CRCRO
Chart Recorder
Ten
inch temperature recorder in case (requires field mounting)
CRCPWMTC Control Panel/Microprocessor Temperature Control *
Control (CP6S) and associated Refrigeration Modifications – surface
mounted control panel w/ microprocessor temperature controller. Provides
+/- 2.0°C Uniformity and +/- 1.0°C Variation. (Can only be used w/ the
Ceiling Mount Refrigeration Systems. The 4’X5’
models cannot have the control panel and/or chart recorder mounted on
the front of the Walk-in. It must be located on a building wall separate
from the Walk-in or on the side of the Walk-in).
CRCPWMTCCR Control/Microprocessor Temp Control/Chart Recorder*
Control (CP6L) and associated Refrigeration Modifications - surface
mounted control panel w/ microprocessor temperature controller and ten
inch temperature recorder. Provides +/- 2.0°C Uniformity and +/- 1.0°C
Variation. (Can only be used w/ the Ceiling Mount Refrigeration Systems.
The 4’X5’ models cannot have the control panel and/or chart recorder
mounted on the front of the Walk-in. It must be located on a building
wall separate from the Walk-in or on the side of the Walk-in).
CRCPMTHC Control Panel/Microprocessor Temp & Humidity Control
*
Control (CP8S replaces standard control provided on 55° to 4°C Warm
Rooms ) and associated Refrigeration Modifications – surface mounted
control panel w/ microprocessor temp/humidity controller. Provides +/-
1°C Uniformity and +/- 0.5°C Variation. This option can only be used w/
the 55° to 4°C Warm Room w/ the Ceiling Mount Refrigeration Systems at
set points of 4°C & above.
CRCPMTCRHC Control Panel/Microprocessor Temp. & Humid. Control
w/Chart Recorder*
Control (CP8L replaces standard control provided on 55° to 4°C Warm
Rooms ) and associated Refrigeration Modifications - surface mounted
control panel w/ microprocessor temperature/humidity controller and ten
inch temp/humidity recorder. Provides +/- 1°C Uniformity and +/- 0.5°C
Variation. This option can only be used w/ the 55° to 4°C Warm Room w/
the Ceiling Mount Refrigeration Systems at setpoints of 4°C and above.
CRHC
Humidifier Centrifugal
Provides a humidity range of ambient up to 95% RH @ 4°-40°C set
points
(based on a ambient of 23°C and 50%, w/ the door closed). Requires
10-100 psig of low mineral content water, less than 10 grains/gallon.
(Can only be used w/ the 55° to 4°C Warm Room and Ceiling Mount
Refrigeration Systems only, and can not operate below 4°C set point).
Requires the Control Panel option to control the humidifier.
CRDESS Dehumidifier Desiccant
Provides a humidity range of ambient down to 40% RH @ 4°C-24°C, 20% RH @
25°C -55°C (based on a ambient of 23°C and 50%, w/ the door closed). The
Dehumidifier requires 115 volt / 20 amp service. (Can only be used w/
the 55° to 2°C Warm Room and Ceiling Mount Refrigeration Systems only,
and can not operate below 4°C setpoint. Requires Control Panel option to
control dehumidifier).
Temperature Uniformity is defined as:
the temperature change of each
of twelve type T-24 Gauge
Thermocouples with 1 oz.
brass slugs located on a horizontal plane 40” from the
floor, 12” from the walls, as measured over a 24 hour
period.
Temperature Variation is defined as:
the temperature variation of the single product sensing
element measured over a 24 hour period. Uniformity
and Variation information is based on ambient conditions
of 23°C and 50% RH and they will vary more; if the
ambient conditions change, on freezers during defrosts
periods, and if the product or other changes cause
interference to the airflow. Walk-ins (Standard)
w/out control panels provide +/- 3.0°C Uniformity and
+/- 2.0°C Variation (excludes defrost periods on
freezers). Walk-ins w/ control panels options provide
+/- 2.0°C Uniformity and +/- 1.0°C Variation
(excludes defrost periods on freezers). Walk-ins w/
hot-gas by pass and controls provide +/- 1.0°C
Uniformity and +/- 0.5°C Variation.
CR30DOOR Door 30” wide
30”
door in lieu of standard 26”. (If the standard shelving kit is used with
this wider door it may extend into the door opening).
CR36DOOR Door 36” wide
36”
door in lieu of standard 26”. (If the standard shelving kit is used with
this wider door it may extend into the door opening)
CRDUPOUT Electrical Duplex Outlet
Surface mounted duplex outlets. Maximum 4 outlets per room, field
installed 6’ and 8’. (Confirm the wattage produced by
the users electrical devices is w/in the capacity of the refrigeration
system. Walk-ins can have up to four (4) duplex outlets).
CREXTRMP Exterior Ramp
36
inches wide.
CRHVP
Heated Viewport
14”X14” viewport in the door
CRHKIT Heater Kit
Required on coolers located outdoors where the ambient temperature is
below freezing (0°C).
CRHILODIG Hi/Lo Digital Alarm
Provided with a shelf for field mounting availability.
CRTRANSKIT Transformer Kit
Used
with some freezer systems. Reduces customer 230/60/1 to 208/60/1
electrical. (Shipped loose,
for field installation).
CRRALARM Refrigerant Alarm
Refrigerant leak detection monitoring may be required, per the 1994
Uniform Mechanical Code. Some areas specifically affected are Houston,
TX and Portland, OR. Contact your General Contractor and/or local
Building Inspector for compliance requirements. We can provide the
refrigerant leak detector, with an audible/visual alarm upon request.
CRREMREFSYS Remote Refrigeration System
Refrigeration Systems include ambient controls, weather-proof hoods,
pre-charged systems, with quick connects for simple field connections to
pre-charged lines of your choice. Consult factory for application,
pricing and ship date.
(accessories) SHELVING KITS- U-SHAPED
Specially designed Shelving Kits are available for all Walk-in units. By
using a support clip, these shelving layouts utilize maximum space for
storage leaving the 26” door opening clear of end standards. For your
convenience, our Walk-in Room price lists have columns with
both 3 and 4 tier
shelving included.
(accessories) SHELVING SYSTEMS
Chrome Shelving
is shown as Standard shelving in
the Price Book. Quick, easy assembly,
with rigid construction.
Stronger shelves, with flexible shelf adjustment
in 1” increments.
Click here to request a quote.
|